- Country of manufactureRussia
Telephone station cables with single - wire copper conductors, PVC - plastic insulation and PVC - plastic sheath, with a foil - coated lavsan screen, including flame retardant.
Telephone station cables are designed for installation of low - frequency station equipment.
Fire hazard class according to GOST 31565 - 2012: P1b.8.2.5.4
OKPD2 CODE:
Brand design
1. Conductor - soft round copper wire.
2. Insulation - PVC compound.
3. Twisted pair or three.
4. Twisted elementary beams.
5. Twisted core.
6. Belt insulation - polyethylene terephthalate tape.
7. Screen - foil - clad lavsan, copper contact wire is laid under the screen.
8. Sheath - made of PVC compound of various colors, in TSVng (A) cable - made of PVC compound of low flammability.
Specifications
The type of climatic modification is UHL, and for the cable of the TSV brand it is also T, placement category 4 in accordance with GOST 15150.
Operating temperature range from - 20 ° С to 50 ° С.
Relative humidity at temperatures up to 35 ° C - up to 98% .
Installation and laying of cables is carried out at a temperature not lower than - 10 ° С.
The bending radius of cables is at least 10 diameters along the sheath.
Electrical resistance of TPG:
- for TPG with a diameter of 0.4 mm - no more than 148 Ohm / km;
- for TPG with a diameter of 0.5 mm - no more than 95 Ohm / km.
Electrical resistance of TPZh insulation - not less than 100 MOhm / km.
Test voltage between cores and screen for 1 min:
- direct current - not less than 1500 V;
- alternating current with a frequency of 50 Hz - not less than 1000 V.
Electric capacity of working pairs over a length of 1 km (reference value) - no more than 100 nF.
Attenuation coefficient at a frequency of 1000 Hz and a length of 1 km of cable with TPZh diameter (reference value):
- 0.4 mm - no more than 2.4 dB;
- 0.5 mm - no more than 1.9 dB.
The construction length of the cables is at least 200 m.
The minimum service life is 15 years.
The warranty period is 3 years.
Name | Characteristic | The weight | Diameter |
---|---|---|---|
TSVng (A) 103x2x0.4 200 V TU 16.K71 - 005 - 87 | Electric cable | 518.45 | 19.2 |
TSVng (A) 103x2x0.5 200 V TU 16.K71 - 005 - 87 | Electric cable | 689.88 | 21.3 |
TSVng (A) 103x2x0.7 200 V TU 16.K71 - 005 - 87 | Electric cable | 1253 | - |
TSVng (A) 10x2x0.4 200 V TU 16.K71 - 005 - 87 | Electric cable | 78.049 | eight |
TSVng (A) 10x2x0.5 200 V TU 16.K71 - 005 - 87 | Electric cable | 98.071 | nine |
TSVng (A) 16x2x0.4 200 V TU 16.K71 - 005 - 87 | Electric cable | 103.192 | 8.6 |
TSVng (A) 16x2x0.5 200 V TU 16.K71 - 005 - 87 | Electric cable | 131.74 | 9.4 |
TSVng (A) 20x2x0.4 200 V TU 16.K71 - 005 - 87 | Electric cable | 122.682 | 9.4 |
TSVng (A) 20x2x0.5 200 V TU 16.K71 - 005 - 87 | Electric cable | 157.044 | 10.2 |
TSVng (A) 30x2x0.4 200 V TU 16.K71 - 005 - 87 | Electric cable | 169.009 | eleven |
TSVng (A) 30x2x0.5 200 V TU 16.K71 - 005 - 87 | Electric cable | 226.416 | 12.3 |
ТСВнг(А) 41х2х0,4 200 В ТУ 16.К71 - 005 - 87 | Электрокабель | 230.764 | 12.8 |
ТСВнг(А) 41х2х0,5 200 В ТУ 16.К71 - 005 - 87 | Электрокабель | 301.205 | 14.1 |
ТСВнг(А) 5х2х0,4 200 В ТУ 16.К71 - 005 - 87 | Электрокабель | 50.497 | 6.5 |
ТСВнг(А) 5х2х0,5 200 В ТУ 16.К71 - 005 - 87 | Электрокабель | 60.508 | 7 |
ТСВнг(А) 5х3х0,5 200 В ТУ 16.К71 - 005 - 87 | Электрокабель | 190.629 | 6.8 |