Telephone cable for structured cable communication systems.
Manufactured according to TU 16.K01 - 50 - 2006.
Designed for operation on subscriber access networks equipped with digital subscriber multiplexing systems (xDSL), to ensure the transmission of information in the frequency range of use up to:
- 16 MHz (category 3);
- 100 MHz (category
Brand design
1. Conductive conductors - single - wire of soft copper wire with a nominal diameter of 0.51 mm.
2. Insulation - made of polypropylene, applied as a continuous layer.
3. Twisted pair - consists of two insulated conductors, differing in color, twisted in pairs with coordinated pitches.
4. Core - twisted pairs are twisted into elementary 2, 3 or 4 - paired bundles.
5. Belt insulation - made of polymer tape with an overlap of at least 25% .
6. Screen - applied longitudinally from an alumopolymer tape. Tinned copper contact wire is laid under the screen.
7. Sheath - made of polyethylene.
Specifications
The type of climatic modification in accordance with GOST 15150 - UHL, placement categories 1, 2.
Operating temperature range: - 50 ° C to 60 ° C.
Relative humidity at temperatures up to 35 ° C: up to 98% .
The cable is installed at a temperature: not lower than - 15 ° С.
Permissible bending radius of cables: at least 10 outer diameters.
Bending radius during cable operation: not less than 10 outer diameters.
The tensile load of cables during laying and operation should be no more than 50 N / mm2 of the total cross - section of conductive conductors.
Electrical resistance of a current - carrying conductor to a direct current, recalculated per 1 km of length and a temperature of 20 ° C: no more than 95.9 - 82 ohms.
Electrical resistance of insulation, recalculated for 1 km of length and temperature no more: 6500 megohms.
The ohmic asymmetry of the veins in the working pair over a length of 1 km should be: no more than 2% .
Capacity of cables: 10 - 100 pairs.
Face - to - face length:
10, 16, 24, 25, 32, 48, 50 pairs: not less than 400 m;
64 and 100 pairs: not less than 300 m.
Minimum cable life: 25 years.
Warranty period of operation: 2 years.
The warranty period starts from the date of putting the cables into operation, but no later than 6 months from the date of manufacture.
Name | Characteristic | The weight | Diameter |
---|---|---|---|
TNVPP 100x2x0.51 3 cat. 200V TU 16.K01 - 50 - 2006 | Electric cable | 704.476 | - |
TNVPP 100x2x0.51 5 cat. 200V TU 16.K01 - 50 - 2006 | Electric cable | 704.476 | - |
TNVPP 10x2x0.51 3 cat. 200V TU 16.K01 - 50 - 2006 | Electric cable | 98.114 | - |
TNVPP 10x2x0.51 5 cat. 200V TU 16.K01 - 50 - 2006 | Electric cable | 98.114 | - |
TNVPP 16x2x0.51 5 cat. 200V TU 16.K01 - 50 - 2006 | Electric cable | 138.185 | - |
TNVPP 25x2x0.51 3 cat. 200V TU 16.K01 - 50 - 2006 | Electric cable | 205.529 | - |
ТНВПП 25х2х0,51 5 кат. 200В ТУ 16.К01 - 50 - 2006 | Электрокабель | 205.529 | - |
ТНВПП 50х2х0,51 3 кат. 200В ТУ 16.К01 - 50 - 2006 | Электрокабель | 351.356 | - |
ТНВПП 50х2х0,51 5 кат. 200В ТУ 16.К01 - 50 - 2006 | Электрокабель | 351.356 | - |