- ПоставщикРТ-Комплект, ООО
The TNU turbo-pump installation is intended for food of a hydraulic system of object on emergency operation and at land service.
Air parameters on an entrance to the unit:
1. Pressure is absolute, 2,85-5,9 - an ata
2. Temperature, + (140-250) - °C
3. An expense, to 0,55 -кг / with
Parameters of working liquid on an entrance to the unit:
4. Temperature, (-60)-(+170) - °C
5. Pressure is absolute, 2-5,5 - an ata
Parameter of the consumed current (constant)
6. Tension, 27±10% - In
7. Current, 1,5 - And
Parameters of working liquid at the exit from the unit
8. Excessive pressure, 140-240 - kgf/cm2
9. Double amplitude of a pulsation of pressure, no more than 30 - kgf/cm2
10. Giving of the pump, not less than 60 -л / mines
Start parameters
11. Start time, no more than 5 - with
12. Altitude of start, to 3000 - m
13. Ambient temperature, (-60)-(+160) - °C
14. Time of continuous work, 30 - mines
Dimensions
15. Length, 463 - mm
16. Width, 205 - mm
17. Height, 318 - mm
18. Weight, no more than 20 - kg