Technical characteristics
- BrandЭлектроника и связь
- Country of manufactureRussia
Description
RVE-3A YAL4.544.000-47
Timer of RVE-3A YaL4.544.000-47 low-current with the unregulated fixed excerpts of time with one contact exit having one switching contact or with one contactless exit.
RVE-3A relays are intended for switching of electric chains of direct and alternating current with endurance of time from 0,05 to 900 pages.
Are made in two modifications:
- RVE3A – tight, in the metal case,
- RVE3B – moisture-proof in the plastic case.
Are issued in climatic modifications in accordance with GOST 15150–69:
- UHL - RVE3A YAL4.544.000-18...-67, RVE3B YAL4.544.000-118...-167,
- In and T - RVE3A-T YaL4.544.001-18...-67, RVE3B-T YaL4.544.001-118...-167.
The RVE-ZA relay conforms to requirements of GOST 16120-86 and specifications of YaL0.454.010 of TU.
Technical characteristics of the RVE-3A relay:
• Food current - constant.
• Working supply voltage...... 27B.
• Consumption current at the working tension equal to 32 V:
- no more than 10 ma – before operation,
- 15–45 ma – after operation.
• Isolation resistance between current carrying elements, between current carrying elements and the case, megohm, not less:
- in normal climatic conditions the power-supply circuit is cut off power...... 200
- in the conditions of the increased humidity...... 10
- at the maximum temperature after endurance of a power-supply circuit of the relay under the working tension...... 20
• Test alternating voltage between current carrying elements and the case, between current carrying elements, In:
- in normal climatic conditions:
- between current carrying elements and the case...... 350
- between current carrying elements...... 180
- in the conditions of the increased humidity...... 180
- with the lowered atmospheric pressure...... 180
• Resistance of contacts of an electric chain during acceptance delivery measured at a voltage of 61 V and current 100010 ma...... no more than 1,6 Ohms.
• Mass of the relay, no more:
– RVE3A of execution YaL4.544.000-18...-41,-66,-67, YaL4.544.001-18...-41,-66,-67...... 70 g.
– RVE3A of execution YaL4.544.000-42...-65, YaL4.544.001-42...-65...... 60 g.
– RVE3B of execution YaL4.544.000-118...-167, YaL4.544.001-118...-167...... 40 g
• Change of temperatures...... from minus 60 to plus 85 C.
• The increased relative humidity of air...... to 98 at a temperature no more than 35 With
• The minimum service life and a relay keeping at storage in the conditions of the heated storage, and also built in in the protected equipment or being in a set the ZIP...... 12 years.
Timer of RVE-3A YaL4.544.000-47 low-current with the unregulated fixed excerpts of time with one contact exit having one switching contact or with one contactless exit.
RVE-3A relays are intended for switching of electric chains of direct and alternating current with endurance of time from 0,05 to 900 pages.
Are made in two modifications:
- RVE3A – tight, in the metal case,
- RVE3B – moisture-proof in the plastic case.
Are issued in climatic modifications in accordance with GOST 15150–69:
- UHL - RVE3A YAL4.544.000-18...-67, RVE3B YAL4.544.000-118...-167,
- In and T - RVE3A-T YaL4.544.001-18...-67, RVE3B-T YaL4.544.001-118...-167.
The RVE-ZA relay conforms to requirements of GOST 16120-86 and specifications of YaL0.454.010 of TU.
Technical characteristics of the RVE-3A relay:
• Food current - constant.
• Working supply voltage...... 27B.
• Consumption current at the working tension equal to 32 V:
- no more than 10 ma – before operation,
- 15–45 ma – after operation.
• Isolation resistance between current carrying elements, between current carrying elements and the case, megohm, not less:
- in normal climatic conditions the power-supply circuit is cut off power...... 200
- in the conditions of the increased humidity...... 10
- at the maximum temperature after endurance of a power-supply circuit of the relay under the working tension...... 20
• Test alternating voltage between current carrying elements and the case, between current carrying elements, In:
- in normal climatic conditions:
- between current carrying elements and the case...... 350
- between current carrying elements...... 180
- in the conditions of the increased humidity...... 180
- with the lowered atmospheric pressure...... 180
• Resistance of contacts of an electric chain during acceptance delivery measured at a voltage of 61 V and current 100010 ma...... no more than 1,6 Ohms.
• Mass of the relay, no more:
– RVE3A of execution YaL4.544.000-18...-41,-66,-67, YaL4.544.001-18...-41,-66,-67...... 70 g.
– RVE3A of execution YaL4.544.000-42...-65, YaL4.544.001-42...-65...... 60 g.
– RVE3B of execution YaL4.544.000-118...-167, YaL4.544.001-118...-167...... 40 g
• Change of temperatures...... from minus 60 to plus 85 C.
• The increased relative humidity of air...... to 98 at a temperature no more than 35 With
• The minimum service life and a relay keeping at storage in the conditions of the heated storage, and also built in in the protected equipment or being in a set the ZIP...... 12 years.
Under the order, 14 days.
Similar company products
Contact the seller
Timer of RVE-3A YaL4.544.000-47