- BrandАООТ Северная Заря, СПб
- Country of manufactureUSSR
- ColorGrey
- Voltage27 V
RVE - 3A YAL4.544.000 - 26
Timer of RVE - 3A YaL4.544.000 - 26 low - current with the unregulated fixed excerpts of time with one contact exit having one switching contact or with one contactless exit.
RVE - 3A relays are intended for switching of electric chains of direct and alternating current with endurance of time from 0,05 to 900 pages.
Are made in two modifications:
- RVE3A – tight, in the metal case,
- RVE3B – moisture - proof in the plastic case.
Are issued in climatic modifications in accordance with GOST 15150–69:
- UHL - RVE3A YAL4.544.000 - 18.. . - 67, RVE3B YAL4.544.000 - 118.. . - 167,
- In and T - RVE3A - T YaL4.544.001 - 18.. . - 67, RVE3B - T YaL4.544.001 - 118.. . - 167.
The RVE - ZA relay conforms to requirements of GOST 16120 - 86 and specifications of YaL0.454.010 of TU.
Technical characteristics of the RVE - 3A relay:
• Food current - constant.
• Working supply voltage. . . . . . 27B.
• Consumption current at the working tension equal to 32 V:
- no more than 10 ma – before operation,
- 15–45 ma – after operation.
• Isolation resistance between current carrying elements, between current carrying elements and the case, megohm, not less:
- in normal climatic conditions the power - supply circuit is cut off power. . . . . . 200
- in the conditions of the increased humidity. . . . . . 10
- at the maximum temperature after endurance of a power - supply circuit of the relay under the working tension. . . . . . 20
• Test alternating voltage between current carrying elements and the case, between current carrying elements, In:
- in normal climatic conditions:
- between current carrying elements and the case. . . . . . 350
- between current carrying elements. . . . . . 180
- in the conditions of the increased humidity. . . . . . 180
- with the lowered atmospheric pressure. . . . . . 180
• Resistance of contacts of an electric chain during acceptance delivery measured at a voltage of 61 V and current 100010 ma. . . . . . no more than 1,6 Ohms.
• Mass of the relay, no more:
– RVE3A of execution YaL4.544.000 - 18.. . - 41, - 66, - 67, YaL4.544.001 - 18.. . - 41, - 66, - 67.. . . . . 70 g.
– RVE3A of execution YaL4.544.000 - 42.. . - 65, YaL4.544.001 - 42.. . - 65.. . . . . 60 g.
– RVE3B of execution YaL4.544.000 - 118.. . - 167, YaL4.544.001 - 118.. . - 167.. . . . . 40 g
• Change of temperatures. . . . . . from minus 60 to plus 85 C.
• The increased relative humidity of air. . . . . . to 98 at a temperature no more than 35 With
• The minimum service life and a relay keeping at storage in the conditions of the heated storage, and also built in in the protected equipment or being in a set the ZIP. . . . . . 12 years.