Technical characteristics
- BrandЭлектроника и связь
- Country of manufactureRussia
Description
The RVE-1A RS4.544.000-49 relay upgraded tight, electronic, static, with one switching contact, is intended for switching of electric chains of direct and alternating current with the fixed excerpts of time from 0,05 to 180 pages.
The RVE-1A relay conforms to requirements of GOST 16121-86 and specifications of YaL0.454.008 of TU.
Hold time of the relay:
RVE-1A RS4.544.000-40 - 0,05 sec.
RVE-1A RS4.544.000-41 - 0,1 sec.
RVE-1A RS4.544.000-42 - 0,5 sec.
RVE-1A RS4.544.000-43 - 1 sec.
RVE-1A RS4.544.000-44 - 2 sec.
RVE-1A RS4.544.000-45 - 3 sec.
RVE-1A RS4.544.000-46 - 4 sec.
RVE-1A RS4.544.000-47 - 5 sec.
RVE-1A RS4.544.000-48 - 10 sec.
RVE-1A RS4.544.000-49 - 20 sec.
RVE-1A RS4.544.000-50 - 30 sec.
RVE-1A RS4.544.000-51 - 45 sec.
RVE-1A RS4.544.000-52 - 60 sec.
RVE-1A RS4.544.000-53 - 90 sec.
RVE-1A RS4.544.000-54 - 120 sec.
RVE-1A RS4.544.000-55 - 180 sec.
Technical characteristics.
Food current - constant.
Isolation resistance between current carrying elements, between current carrying elements and the case, megohm, not less:
- in normal climatic conditions the power-supply circuit is cut off power - 200
- in the conditions of the increased humidity - 10
- at the maximum temperature after endurance of a power-supply circuit of the relay under the working tension - 20
Test alternating voltage between current carrying elements and the case, between the closing contacts, In:
in normal climatic conditions:
- between current carrying elements and the case - 350
- between the closing contacts - 180
- in the conditions of the increased humidity - 180
- with the lowered atmospheric pressure - 180
Material of contacts - Zlsrmgn2-97.
Resistance of electric contact during delivery no more than 1,6 Ohms.
The mass of the relay are no more than 160 g.
The minimum service life and a relay keeping at storage in the conditions of the heated storage, and also built in in the protected equipment or being in a set the ZIP - 12 years.
The RVE-1A relay conforms to requirements of GOST 16121-86 and specifications of YaL0.454.008 of TU.
Hold time of the relay:
RVE-1A RS4.544.000-40 - 0,05 sec.
RVE-1A RS4.544.000-41 - 0,1 sec.
RVE-1A RS4.544.000-42 - 0,5 sec.
RVE-1A RS4.544.000-43 - 1 sec.
RVE-1A RS4.544.000-44 - 2 sec.
RVE-1A RS4.544.000-45 - 3 sec.
RVE-1A RS4.544.000-46 - 4 sec.
RVE-1A RS4.544.000-47 - 5 sec.
RVE-1A RS4.544.000-48 - 10 sec.
RVE-1A RS4.544.000-49 - 20 sec.
RVE-1A RS4.544.000-50 - 30 sec.
RVE-1A RS4.544.000-51 - 45 sec.
RVE-1A RS4.544.000-52 - 60 sec.
RVE-1A RS4.544.000-53 - 90 sec.
RVE-1A RS4.544.000-54 - 120 sec.
RVE-1A RS4.544.000-55 - 180 sec.
Technical characteristics.
Food current - constant.
Isolation resistance between current carrying elements, between current carrying elements and the case, megohm, not less:
- in normal climatic conditions the power-supply circuit is cut off power - 200
- in the conditions of the increased humidity - 10
- at the maximum temperature after endurance of a power-supply circuit of the relay under the working tension - 20
Test alternating voltage between current carrying elements and the case, between the closing contacts, In:
in normal climatic conditions:
- between current carrying elements and the case - 350
- between the closing contacts - 180
- in the conditions of the increased humidity - 180
- with the lowered atmospheric pressure - 180
Material of contacts - Zlsrmgn2-97.
Resistance of electric contact during delivery no more than 1,6 Ohms.
The mass of the relay are no more than 160 g.
The minimum service life and a relay keeping at storage in the conditions of the heated storage, and also built in in the protected equipment or being in a set the ZIP - 12 years.
Under the order, 14 days.
Similar company products
Contact the seller
Timer of RVE-1A RS4.544.000-49