The furnace electric industrial for annealing of the personal computer 6 / 7-3
- Customer pickup,
- Courier
- In detail
- BrandНПФ Технотрон
- Country of manufactureRussia
- Промышленная Электропечь для отжига ПК 6/7-3
Industrial Electric Annealing Furnace
The electric furnace is designed to conduct thermal processes of metal products (tempering, annealing, stamping, etc. ) in air at temperatures up to 900 degrees, weighing up to 3000 kg.
Specifications
Maximum temperature, ° C 700 - 900
Workspace environment air
Temperature rise rate, at least ° C / hour: 50
Sizes of a working chamber, mm, not less (LxWxH): 4000x1200x1200
Environment in the working space: air Temperature difference at various points in the working space of the furnace at steady state thermal conditions at maximum temperature, ° C: ± 5
Installed power of heaters, kW no more than 300
Temperature regulation: automatic Temperature controller: “Thermodat 17E6 System of forced circulation of the furnace atmosphere 2 fans Graduation of thermocouple TXA
Parameters of the mains: Voltage, V 380 Frequency, Hz 50; Number of phases 3 Protection rating of control cabinet: IP 60
Door Type: Electromechanical Lift
Type of hearth: retractable with electromechanical drive
Maximum dimensions of the furnace (without paths), (LxWxH) mm 5200x2150x4100
Number of regulation zones 3
Maximum load under, kg 3000
OPERATING MODES
Automatic Semi - automatic Tuning Mode
CONTENTS OF DELIVERY
Hearth furnace
Electric control cabinet
A set of wires connecting the control cabinet to the furnace
Thermocouples Passport Operating Instructions
OPERATING CONDITIONS
Altitude not more than 1000 m.
The environment must be non - explosive, not contain a significant amount of conductive dust, water vapor and aggressive gases in concentrations that have a harmful effect on the components and materials of the electric furnace.
Ambient temperature from + 5 ° С to + 35 ° С.
The relative humidity of the environment is not more than 80% at a temperature of 25 ° C.
During storage and operation, the electric furnace must not be subjected to shock and vibration.
Type of climatic modification UHL 4.1 in accordance with GOST 15150 - 69.
Power supply network - in accordance with GOST 32144 - 2013.
The safety electric furnace complies with GOST R 50014.1 - 82.