Technical characteristics
- Brand«АС-501М»
- Country of manufactureBelarus
- GTIN-
Description
The device for receiving and control firefighting transport "AS - 501M" BI - Ryu 01.318.00.000 (hereinafter - PPKP - T) is designed to receive signals via two - wire communication lines from fire detectors located in the premises and service compartments of a passenger car and to notify service personnel about the occurrence fire with an indication of the place (address) where the fire factors were found.
PPKP - T is designed for round - the - clock continuous operation when powered from the on - board DC network (batteries) of the car with a voltage of 50 or 110 V. The operating range of supply voltages PPKP - T is from 35 to 160 V without additional switching.
BASIC TECHNICAL DATA AND CHARACTERISTICS
Parameter | Unit rev. | Value |
Number of alarm loops | PCS. | 16 |
DC supply voltage | IN | 50/110 |
Supply voltage range | IN | 35 . . . 150 |
Power consumption | W | |
- in standby mode | ≤ 15 | |
- in the standby mode issue | ≤ 20 | |
Amplitude of impulse voltage on the alarm loop | IN | 12 ± 2 |
Maximum current commutated by relay signals transmitting signals "Ready", "Fire", "Malfunction", "ASPT" to the central monitoring console and train systems at a voltage of 160V | AND | four |
Designed to operate at up to 95% relative humidity | ° C | + 35 |
Insulation resistance between housing and contacts for power connection | MOhm | ≥ 20 |
dimensions | mm | 560x120x105 |
Weight | Kg | ≤ 8 |
Warranty period of operation | month | ≥ 24 |
Contact the seller
Fire control device for transport AS-501M