- BrandЭлектроника и связь
- Country of manufactureRussia
TGI1-700/25
Pulse modulator TGI1-700/25 thyratron is intended for switching in the scheme of the linear modulator.
Is issued in glass registration.
The socle is special, 4-shtyrkovy.
The cylinder is filled with hydrogen.
The cathode is oxidic, indirect heat.
Time of a warming up of 7 min.
Works in any situation.
Ambient temperature is from-60 to +90 Pages.
Cooling is natural.
Service life - not less than 400 h.
Weight - no more than 2,5 kg.
Nominal electric data of TGI1-700/25:
Heat tension, In...... 6,3
Heat current, And...... 20
Amplitude of direct and return tension on the anode, kV...... 25
Current in an anode chain in an impulse, And...... 700
Output power in an impulse, kW...... 8700
Average output power, kW...... 12,5
Tension on a grid, In...... not less than 700
Current in a grid chain in an impulse, And...... 3-8
Impulse duration, microsecond...... 2,8
Periodic instability of ignition at a tension on the anode of 10 kV, microsecond...... no more than 0,03
Power failure on thyratron in an impulse, In...... no more than 200
Fluctuation of time of delay of current in an anode chain in an impulse in relation to tension impulse on a grid at strictly constant parameters of the setting fire impulse, microsecond...... no more than 0,4
Maximum permissible electrical quantities of TGI1-700/25:
The largest tension of heat, In...... 6,6
The smallest tension of heat, In...... 6,0
The largest amplitude of direct and return tension, kV...... 25
The largest amplitude of the return tension on the anode during the first 25 microseconds after passing of an impulse of current, kV...... 5
The greatest current in an anode chain in an impulse, And...... 730
The greatest value of average current in an anode chain, And...... 1
Service conditions:
1. The lamp panel and fastening of thyratron in the scheme have to provide free access of air to the lower surface of a socle and to a thyratron flask.
2. Increase in anode tension to 25 kV after a warming up of the cathode has to be made within 0,5-1 min. In the course of work of thyratron in the pulse mode instant inclusions and giving of full tension of the anode are allowed.
3. At a tension on the anode higher than 20 kV thyratron creates the intensive x-ray radiation demanding protection.
4. The loading resistance mismatch (about 5%) with a wave resistance of the line is necessary for creation on thyratron of negative tension after passing of an impulse of current.