- BrandЭлектроника и связь
- Country of manufactureRussia
TGI1-35/3
Pulse modulator TGI1-35/3 thyratron is intended for switching in schemes of linear modulators.
Is issued in glass registration.
The socle is special, 4-shtyrkovy.
The cylinder is filled with hydrogen.
The cathode is oxidic, indirect heat.
Time of a warming up of 3 min.
Works in any situation.
Ambient temperature is from-60 to + 90C.
Cooling is natural.
Service life - not less than 500 h.
Weight - no more than 80 g.
Nominal electric data of TGI1-35/3:
Heat tension...... 6,3 B
Heat current...... 2,13,0 A
Current in an anode chain in an impulse...... 35 A
Average value of current in an anode chain...... 45 ma
Impulse duration...... 0,2 — 6 microsec
Dispersion of the front of an impulse of current of the anode from an impulse to an impulse...... no more than 0,04 microsec
Power failure on thyratron in an impulse...... no more than 140 V
Characteristic of ignition positive.
Limit operational data of TGI1-35/3:
Heat tension...... 5,8 - 6,8 B
Anode tension direct and the return...... no more than 3 kV
Warming up time...... 3 min.
Maximum temperature of a cylinder...... 185 °C
Data of impulses of current in an anode chain:
- maximum amplitude of current of the anode...... 35 A
- maximum average current of the anode...... 0,045 A
- impulse duration...... 0,2 6 microsec
Parameters of the setting fire grid impulse:
- maximum amplitude of tension...... 150 V
- maximum amplitude of current...... 60 ma
- impulse duration...... 1 — 6 microsec
- steepness of the front of an impulse...... not less than 300 microsec
Given to a net chain of thyratron:
- resistor resistance in a cathodic chain of the cathodic repeater...... no more than 12,5 kOhm
- leak resistor resistance...... 30 - 100 kOhm
- capacity of the dividing condenser...... not less than 2000 pf
Service conditions:
1. For thyratron ignition on a grid the positive rectangular impulse of tension has to be given.
2. For a net chain the following sizes are recommended: - resistance in a chain of the cathode of the cathodic repeater no more than 12,5 lumps, - resistance of leakage of a grid from 30 to 100 lump, - the capacity of the dividing condenser in a grid chain not less than 2000 pf.
3. Sizes of resistance of leakage of a grid and capacity of the dividing condenser are selected so that the constant of time of a chain did not exceed one third of the period of repetition of impulses.