TGI1-2500/50
Pulse modulator thyratron. TGI1-2500/50 is intended for use as the switching device in the linear modulator.
The cathode is oxidic, indirect heat.
Filling – hydrogen.
Cooling – liquid.
Registration – ceramic-metal.
Rating electric data of TGI1-2500/50:
Current of heat of the generator of hydrogen...... 2,6 A
Anode current (impulse amplitude)...... 2500 A
Anode current (average value)...... 4 A
Periodic instability of ignition...... no more than 0,005 microsec
Power failure between the anode and the cathode...... no more than 250 V
Durability...... not less than 2000 h
Extreme operational parameters:
Heat tension...... 6,0-6,6 B
Anode tension direct...... 10-50 kV
Anode tension the return...... no more than 40 kV
Data of impulses in an anode chain:
- anode current (amplitude value)...... no more than 2500 And
- anode current (average value)...... no more than 4 And
- following frequency...... no more than 400 imp / with
- duration...... no more than 30 microsec
- steepness of increase of the front...... no more than 7000 And/microsec
Parameters of the setting fire grid impulse:
- tension amplitude...... not less than 1200 V
- current in a grid chain...... not less than 12 And
- impulse duration...... 3-10 microsec
- steepness of increase of the front...... 2500-5000 microsec