- BrandSun
- Country of manufactureUkraine
- PurposeExhaust emission control of cars
The 4th component (WITH, NANOSECOND, CO2, O2) DGA-1500 gas analyzer
The diagnostic analyzer of exhaust Sun DGA1500 gases possesses the most achievable parameters for today.
After initial loading and warming up the DGA1500 analyzer is ready to work already in a few minutes and, thanks to intuitive clear interface, does not demand from the operator of special preparation.
The gas analyzer of DGA1500 is equipped with the big graphic LCD display with high resolution, the convenient keyboard for dialogue management and the built-in thermal printer for a conclusion of results of measurement.
Main features:
• It is ideal for certified laboratories. large stations;
• Compact and reliable;
• Gasoline, the Diesel or Combi is available in versions to measurement of 4/5 gases;
• Convenient LCD display of high resolution;
• Practical interactive keyboard;
• Built-in thermal printer;
• Measurement of frequency of rotation (RPM) and temperature of oil
General characteristics: | |
Power supply parameters: | 115-230 V / 1,5 A; 47-63 Hz |
Working temperature: | from-10 to +55 °C |
Overall dimensions of the case (DKHVKHG): | 451 x 181 x 310 mm |
Weight: | 8,9 kg |
Conforms to the standard | ISO 3930. |
Warming up time: | No more than 9 minutes At 23 °C - about 3 minutes |
Minimum time | 1 minute |
Response time: | From 5 to 6 seconds for CO, CO2 and HC 28 of seconds for oxygen (transition from 20,9% to 0,1% for gas from 0% of O2) |
Nominal productivity of the pump: | 6 l/min; minimum: 3,5 l/min |
Changes of pressure of air: | automatic correction on a signal of the built-in sensor of absolute pressure |
Zero accuracy and sensitivity: | automatic compensation |
Reserve automatic pump | + |
Automatic zeroing | + |
At the request of the client (in the COMBO version) the device can be understaffed with a portable dymomer of DSS-3
Dymomer of diesel DSS-3 engines
• Range of measurement of smoke of 0-100%.
• Built-in self-diagnostics, linearization procedure.
• Reliable and strong steel case of the device.
• Adaptation to requirements of GOST