Currency EUR
Strain gage of the membrane M100 type – Yuzhno-Uralskij Vesovoj Zavod, OOO | all.biz
Buy Strain gage of the membrane M100 type
Strain gage of the membrane M100 type

Strain gage of the membrane M100 type

In stock
Reconfirm the price with seller
Shipping:
Seller
Russia, Beloretsk
(View map)
+7(3 
Display phones
Description
Application
Weighing of capacities and tanks.
Thanks to design features strain gages are easily built in weight measuring systems. At the same time high reliability of a vstroyka is provided. Sensors can work in any conditions of environment. Features
  • Sensors are manufactured of materials and the completing best global manufacturers
  • Sealing of the sensor is made by a cover from the stainless steel attached to an elastic element by means of laser welding
  • Each sensor undergoes testing for tightness a helium techeiskatel
  • Strain gages pass tests by reference silozadayushchy cars of production "Tenzo-M". Cars are certified as standards of the first category according to the State testing scheme for gages of force (GOST P 8.663-2009)
  • Strain gages are delivered to the consumer picked up for groups for sharing in scales
  • Warranty period 4 years.

Complete set
  • Execution according to GOST P 8.726-2010: 3000 testing intervals
  • Cable 16m length.
  • Four-wire scheme of connection
  • The screen of a cable is not connected to the strain gage case
  • Explosion-proof execution according to requirements of GOST P51330.0-99 (MEK 60079-0-98), GOST P51330.10-99 (MEK 60079-11-99). OExiaIICT6 X
Options
  • Working range of temperatures:-50... +50 °C
  • Execution according to GOST P 8.726-2010: 1000 testing intervals
  • Length of a cable is from 2 to 100 m
  • Six-wire scheme of connection
  • Supply voltage from 2 to 36B
  • Output resistance 410±1Ом
  • Certificate on checking
  • Metalsleeve

Sensor parameters Unit of measure Value of parameters
Greatest Limit of Measurement (GLM) t
30, 50
Accuracy class in accordance with GOST P 8.726-2010
C1 C3
Number of testing intervals
1000 3000
Minimum testing interval
NPI / 5000 NPI / 10000
Working Coefficient of Transfer (WCT) mV / In 2 ± 0,010 2 ± 0,002
Initial Coefficient of Transfer (ICT) % of RCP <3 <3
The combined error % of RCP ≤ ±0,040 ≤ ±0,020
Creep (30 min.) % of RCP ≤ ±0,049 ≤ ±0,025
Change of NKP from temperature % of RCP/°C ≤ ±0,0028 ≤ ±0,0014
Change of RCP from temperature % of RCP/°C ≤ ±0,0022 ≤ ±0,0011
The greatest supply voltage of a direct current In 12
Resistance is entrance Ohm 750 ±15
Resistance is output Ohm 700 ±1
Isolation resistance GOM ≥ 5
Thermal compensation range °C - 10... +40
Working range of temperatures °C - 30... +50
Range of temperatures of storage °C - 40... +50
Degree of protection in accordance with GOST 14254
IP68
Admissible overload within no more than 1 hour % of NPI 25
Ultimate load % of NPI 300
Sensor material
Stainless steel