STOP WATCH ELECTRONIC "INTEGRAL OF S-01
- Customer pickup,
- Courier
- In detail
(View map)
- BrandИнтеграл
- Country of manufactureBelarus
- TypeElectronic
The certificate on the statement like measuring instruments of BY.C.33.999.A No. 62005 till 04.08.2020.
Stop watches electronic "S-01 Integral" - the electronic device with the independent power supply and the liquid crystal indicator (ZhKI).
The principle of work of a stop watch electronic is based on use of the quartz generator and microprocessor ensuring functioning in all modes and a conclusion of measuring information to ZhKI.
Stop watches ensure functioning in two modes – "stop watch" and "hours". The choice of the mode, management in each mode is made by the corresponding buttons.
In the stop watch mode entering of results of measurements in memory (the maximum number of measurements – 10), reading and deleting of results of measurements is possible.
In the hours mode reproduction twenty four an hour scale of time in hours, minutes and seconds is possible.
Main characteristics:
Name of the characteristic, measurement unit. | Value |
Range of measurements of intervals of time, with | from 0 to 9 h is 59 min. old |
Discretization of the measured time intervals, with | 0,01 |
Limits of the allowed main absolute error of measurement in the stop watch mode in normal service conditions (25 ± 5) °C, with where Tkh – value of the measured time interval, with |
± (9,6 · 10-6 · Tkh + 0,01) |
Limits of the allowed additional absolute error of measurement in the mode of a stop watch caused by an air temperature deviation from normal conditions (25 ± 5) °C in the range of working temperatures from minus 10 °C to 50 °C on 1 °C of change of temperature, with | - 2,2 · 10-6 · Tkh |
The daily course of hours at a temperature (25 ± 5) °C, with / days | ± 1,0 |
The daily course of hours at a temperature (23 ± 5) °C, with / days | ± 0,5 |
The daily course of hours in the range of working temperatures from 1 °C to 45 °C, except for a temperature interval (25 ± 5) °C, with / days | ± 2,5 |
Restoration of the daily course, with / days | ± 0,5 |
Estimated number, no more | 1,6 |
Consumption current at the supply voltage 1,5 B, a mka, no more | 4,0 |
Overall dimensions (length´ vysota'shirina), mm, no more | 77 × 58 × 18 |
Weight, kg, no more | 0,05 |
Service conditions in the stop watch mode: - ambient temperature, °C Service conditions in the mode of hours: - ambient temperature, °C |
from minus 10 to 50 from 1 to 45 |
Transportation conditions: - ambient temperature, °C - relative humidity |
from minus 10 to 50 not less than 98% at 35 °C |