Technical characteristics
  • BrandASP
Description

Sterilizer low - temperature ASP STERRAD 100S

STERRAD 100S is the low - temperature sterilizer based on technology of plasma of STERRAD hydrogen peroxide. It is intended for the medical institutions having a need for bystry and careful sterilization of tools and the equipment, especially hi - tech expensive tools.

The modern low - temperature technology of sterilization and the dry sparing process keep integrity and prolong service life of tools, delicate and sensitive to moisture.

Lack of need of installation of additional expensive systems, including for aeration and water supply, provides economy of costs of medical institution of installation of sterilizing system.

The Bystry cycle of the STERRAD 100S - 54 system of minute - allows to use more often tools and is measurable to cut down your expenses. Thanks to gas - plasma technology, the STERRAD 100S system provides dry, low - temperature sterilization of tools including sensitive to high temperature and humidity. Now you will have tools when you need it. The sterile packed tools are ready to use or storage right after the termination of a cycle, additional conditions on their cooling or aeration are not required for a long time.

Technical characteristics:

General time of a cycle:

Short 54 minutes

Long 72 minutes

Temperature in a cycle of 45 - 55 °C.

Sizes and weight:

Width is 765 mm

Height is 1,660 mm

Depth is 1,020 mm

Weight is 350 kg

Sterilization camera volume - 100 l

Requirements to power supply:

Power supply is three - phase

Voltage is 380 V

Current 16 A

Frequency is 50 Hz

Conditions of the working room:

Temperature is 10 - 40 °C

Humidity of ≤95% (without condensation)

The built - in wheels provide mobility

Camera form - cylindrical

Net volume of the camera is 100 liters

Sizes of shelves (2 regiments):

Top 1 - 700kh425mm

Lower 1 - 760kh325mm

 

Contact the seller