Currency EUR
Separator of secondary steam of SVP-0,2 (TEPLOTERM) – Teploterm TPK, OOO | all.biz
Buy Separator of secondary steam of SVP-0,2 (TEPLOTERM)
Separator of secondary steam of SVP-0,2 (TEPLOTERM)
separator_vtorichnogo_para_svp_0_2_teploterm

Separator of secondary steam of SVP-0,2 (TEPLOTERM)

Products from producer
Custom order, 15 days
Price:
366.56 EUR
Shipping:
Ukraine, Kiev
(View map)
+380 
Display phones
Technical characteristics
  • BrandТеплотерм
  • Country of manufactureUkraine
Description

Separators of secondary steam of SVP (sometimes call a separator of secondary boiling up) are intended for use in systems of a purge of coppers and return of heat where it is important to separate steam of secondary boiling up from a purge for prevention of pollution of a nutritious tank of a copper and/or the surfaces of transfer of heat. Also are suitable for application in systems of collecting and return of condensate.

PRINCIPLE OF WORK:

       Condensate pressure / blowing-off water, coming to a separator of SPVV decreases that leads to secondary boiling up. Secondary steam comes back to system or is used in other technological purposes, for example in system of heating.

INSTALLATION:

      The separator of steam of secondary boiling up of SPVV is mounted vertically thus that the opening of an exit of secondary steam was above. In each separator there is a carving union the G½ size" (vnut.rezba) for installation of the manometer with a compensation tube. For branch from a separator of condensate it is recommended to use the knot of removal of condensate consisting of the filter of a mesh, float-operated kondensatootvodchik, viewing glass, the backpressure valve and shutoff valves. On a separator there is a branch pipe for the safety valve.

 

Name SVP-0,2 SVP-0,3 SVP-0,4 SVP-0,5
Consumption of parokondensatny mix, etc., no more 6,0 10,0 14,0 18,0
Conditional pressure of the case PN16
Working temperature, ° C, no more 250

 

                  OVERALL DIMENSIONS AND NAME OF BRANCH PIPES

 Execution 1

Execution 2

     Size, mm          SVP-0,2         SVP-0,3        SVP-0,4         SVP-0,5    
A1 80 100 150 150
B1 25 40 40 50
B1 80 100 150 150
G1 50 50 80 80
D1 15 15 15 15
In 225 250 270 300
1120 1240 1330 1390
D 219 325 426 530
E 220 290 345 410
850 960 1025 1070
Z 520 555 620 645
And 295 320 345 370
To 260 315 365 420
L 160 160 160 160
M 160 270 370 470
About 16 24 24 24
P 20 20 26 30
R 335 450 585 690

 

 THE RECOMMENDED SCHEME OF CONNECTION

 

OPTIONS AT THE ORDER:

  • isolation of the SVP case;
  • delivery of auxiliary accessories;
  • installation of the water-indicating device for visual control of level;
  • the complete set pressure regulator "to itself" that allows to avoid losses of steam at operation of the safety valve and to ensure stabler functioning of SVP.
Shipping method
Contact the seller
Separator of secondary steam of SVP-0,2 (TEPLOTERM)
Separator of secondary steam of SVP-0,2 (TEPLOTERM)
for
by the goods
Your message must contain at least 20 symbols. The message must not be more than 2000 symbols.
Obligatory field is not filled
The field is wrongly filled
The field is wrongly filled
Compare0
ClearSelected items: 0