Currency EUR
Resistance thermocouple EnI-300 TSM – ITeK BBMV, OOO | all.biz
Buy Resistance thermocouple EnI-300 TSM
Resistance thermocouple EnI-300 TSM

Resistance thermocouple EnI-300 TSM

Products from producer
In stock
Reconfirm the price with seller
Payment:
  • Cash,
  • Cash on delivery,
  • Invoice payment
  • In detail
Shipping:
  • Customer pickup,
  • Courier,
  • Transport company
  • In detail
Seller
Russia, Chelyabinsk
(View map)
+7(3 
Display phones
Technical characteristics
  • BrandИТеК ББМВ, ООО
  • Country of manufactureRussia
Description

Thermal converter of resistance EnI - 300 TSM

Resistance thermocouples are used to measure the temperature of liquid, gaseous, bulk media, dispersed media and suspensions without adhesion of particles, surfaces, as well as aggressive media that do not destroy the protective case and protective fittings of the vehicle.

  • Modular structure (flexible configuration)
  • NSX type: 50P, 100P, Pt100, Pt500, Pt1000, 50M, 100M
  • Connection diagrams: 2 - x, 3 - x, 4 - x - wired
  • Measured temperature range:
  • TCM from - 180 to + 200 ° С; DFT from - 196 to + 660 ° С.
  • Number of sensing elements: 1 or 2
  • Accuracy class АА, А, В, С
  • Calibration interval: 2 years
  • Explosion protection: flameproof enclosure, intrinsically safe electrical circuit
  • Simplicity of design and reliability
  • Possibility of bending, installation in hard - to - reach places, in cable ducts

They are used to measure temperature in energy, chemical, metallurgical, housing and communal services and energy saving and other industries.

Explosion - proof vehicles can be used at facilities in zones of class 0; 1 and 2 according to GOST IEC 60079 - 14 - 2013, where the formation of mixtures of combustible gases and vapors with air of category IIC according to GOST IEC 60079.14 - 2013 of temperature group T1 . . is possible. T6 inclusive.

Main technical characteristics

Table 1

Main characteristics Meaning
Sensor type TSP, TSM
Rated static characteristic of the sensing element (NSX) Pt100, Pt500, Pt1000,50P, 100P, 50M, 100M
Explosion protection "Explosion - proof enclosure" 1Ex d IIC T6GbX, 1Ex d IIC T5GbX, 1Ex d IIC T4 Gb X, except for TC modifications - 03, - 06, - 09.

"Intrinsically safe electrical circuit" - 0Ex ia IIC T6 Ga X, 0Ex ia IIC T5 Ga X, 0Ex ia IIC T4 Ga X c

Body material aluminum alloy, stainless steel, heat - resistant plastic
Fixing the housing cover screw, latch, threaded
Dust and moisture protection IP54, IP55, IP5X, IP65, IP66, IP67, IP68

(depending on housing design)

Measuring transducer with output 4 - 20.20 - 4, 0 - 5 mA, 4 - 20 + HART, Profibus (PA)
Process connection type without fasteners, union, flange
Design of protective fittings without fitting, fixed fitting, movable fitting, with thinning, spring - loaded fitting
Mounting part lengths from 25 to 60,000 mm
External circuit connections terminal block, power supply, including with LCD, free leads
Climatic version according to GOST 15150 - 69 UHL3.1 or U1.1
Average service life up to 20 years depending on the measured medium and application temperature
MTBF depending on the application temperature up to 45,000 hours

Operating conditions

The type of climatic modification of the vehicle in accordance with GOST 15150 - 69: UHL3.1 or U1.1, but for operation at ambient temperature - see table 2, the upper value of the relative humidity of 98% (at 25 ° C) and lower temperatures without condensation moisture

table 2

Vehicle execution Ambient temperature, ° С
version without explosion protection explosion - proof design (Ex ia, Ex d)
without individual entrepreneurs from minus 62 to + 120 ° С from minus 62 to + 95 ° С (Т4);

from minus 62 to + 85 ° С (Т5, Т6)

without housing with extension leads from minus 62 to + 180 ° С
with SP from minus 50 to + 85 ° С (depending on the applied IP)
with IP with LCD from minus 40 to + 85 ° С (depending on the applied IP)

For vehicles in a casing with heating or in a casing with a thermal cover, the lower limit of the ambient temperature is - 70 ° C.

Vehicles can be manufactured for operation in narrower ambient temperatures.

 

https://eni-bbmv.ru/index.php/ru/

Contact the seller
Resistance thermocouple EnI-300 TSM
Resistance thermocouple EnI-300 TSM
Shipping method
Payment method
Compare0
ClearSelected items: 0