- BrandНПП «МАГНИТО-КОНТАКТ»
- Country of manufactureRussia
Passport
Declaration of compliance with the requirements of the Technical Regulations of the Customs Union: TR CU 004/2011 "On the safety of low - voltage equipment"; TR CU 020/2011 "Electromagnetic compatibility of technical equipment" No. RU D - RU. AK01.B.04701 / 19 . Valid from 6.03.2019 to 4.03.2024
Certificate of compliance with the requirements of the Technical Regulations of the Customs Union TR CU 012/2011 "On safety of equipment for operation in explosive atmospheres" No. EAEU RU C - RU. BH02.B.00141 / 19. Valid from 07/03/2019 to 07/02/2024
Declaration of conformity to the requirements of the Technical Regulations of the Customs Union "On the safety of low - voltage equipment" (TR CU 004/2011), the Technical Regulations of the Customs Union "Electromagnetic compatibility of technical means" (TR CU 020/2011) EAEU N RU D - RU. НР15.V. 08437/20 . Valid from 5.10.2020 to 4.10.2025
General information
The junction box is intended for connecting (branching) signal cables, for example, in loops of a fire or security and fire alarm system, communication and telecommunication lines, control systems and automation circuits, as well as connecting terminal devices to loops, etc.
The designation of the box when ordering and in the design documentation of other products consists of the name of the product, order code, designation of technical specifications.
The overall dimensions of the junction box are given in Appendix A.
Box material: ABS plastic or polystyrene (ordering example - see Appendix B).
Main parameters and characteristics
Sheath protection degree according to GOST 14254 - 2015 | IP66 / IP67 |
Transient resistance of two contacts, Ohm | no more than 0.3 |
Operating temperature range, ° С | - 55 . . . 60 |
Maximum relative air humidity, at t + 40 ° С, % | no more than 93 |
Weight, kg | no more than 1.2 |
Average service life, years | not less than 10 |
Diameter of the connected conductors | terminal block PM2 up to 4 mm 2 (AWG 22 - 10) 300V 30A, terminal block T31 up to 2.5mm 2 (AWG 22 - 14) 300V 15A. |
Electrical connections between terminal blocks are presented in Appendix B. Type of terminal blocks, diameter of the connected cable and are selected based on the needs of the customer, according to the ordering example. | |
The box is protected against tampering with the output of the sensor contacts to a separate terminal block. |
Completeness
- junction box - 1 pc.
- passport - 1 pc. (for packaging)
Description of construction
The product body can be:
- base and cover without holes
- equipped with 8 sealed cable glands. with a diameter of the connected cable from 9 to 17 mm *
( * - by agreement with the customer, the product can be supplied with cable glands with a diameter of the connected cable from 9 to 14 mm; from 14 to 17 mm; ).
- equipped with sealed MKV bushings (see table) made of stainless steel 12X18H10T, designed for various cable routing options.
Table 1. Types of cable glands MKV (conventional designation of thread M20)
TYPE OF CABLE INLET MKV | SYMBOL | CABLE PASSING DIAMETER, MM |
---|---|---|
Open cable routing | MKV М20К | 6 - 12 |
Pipe with G1 / 2 thread | MKV М20Т1 / 2 | 6 - 12 |
Pipe with G3 / 4 thread | MKV М20Т3 / 4 | 6 - 12 |
Metal hose RZTs 10 mm | MKV М20КМ10 | 6 - 8 |
Metal hose RZTs 12 mm | MKV М20КМ12 | 6 - 10 |
Metal hose RZTs 15 mm | MKV М20КМ15 | 6 - 12 |
Armored cable | MKV M20V | 6 - 12 |
Double Sealed Armored Cable | MKV M20V2 | 6 - 12 |
Table 2. Types of cable glands MKV (conventional designation of thread M25)
TYPE OF CABLE INLET MKV | SYMBOL | CABLE PASSING DIAMETER, MM |
---|---|---|
Open cable routing | MKV M25K | 10 - 14 |
Pipe with G3 / 4 thread | MKV М25Т3 / 4 | 10 - 14 |
Metal hose RZTs 20 mm | MKV М25КМ20 | 10 - 14 |
Metal hose RZTs 25 mm | MKV М25КМ25 | 10 - 14 |
Armored cable | MKV M25V | 10 - 14 |
Double Sealed Armored Cable | MKV М25V2 | 10 - 14 |
- equipped with metal lead - in couplings VM for metal hoses brands MRPI, MRN, RZ - Ts, RZ - TsKh:
- VM - 15 coupling with ½ "lead - in thread (nominal bore of metal hose 15 mm)
- VM - 20 coupling with ¾ "lead - in thread (nominal bore of metal hose 20 mm)
The installation dimensions of the connecting device are given in Appendix A.
A printed circuit board is installed inside the product body, on which there are screw terminal blocks for connecting the connected conductors.
Placement and installation
- Unscrew the cover fixing screws, remove the cover.
- Check that the cable glands are securely fastened and ensure that the rubber seals are present.
- Feed the cable through the cable gland. Fasten securely inside the cable gland. To ensure a tight seal, the cable gland O - ring must be tightly fastened. Free the insulated cable cores from the outer insulation and cut the ends of the inner insulation to a length of 5..8 mm. Connect the cable conductors to the terminals of the terminal block. Put on the cover, tighten the fastening bolts.
- After installation, seal the cover fixing screw (to be sealed by the installer).
Appendix A. Appearance, overall and installation dimensions of the junction box
Appendix B. Electrical connections on the junction box board
Appendix C. Description of ordering the junction box
Order examples
KVSK "SEVER" PL.8.PS.9 - 14.T31. With this order code, the consumer will be supplied with a box in a polystyrene casing with 8 cable glands, a connected cable diameter of 9 - 14mm, with T31 terminals.
KVSK "SEVER" PL.4.VM15.T31. With this order code, the consumer will be supplied with a box in a polystyrene casing with 4 BM15 couplings under a metal hose with nominal bore 15, with T31 terminals.
KVSK "NORTH" ABS.6.MKV М25КМ20.10 - 14.Т31. With this order code, the consumer will be supplied with a box in a case made of ABS plastic with cable glands MKV M25KM20 (for laying a cable in a metal hose RZTs20) made of stainless steel in the amount of 6 pcs. , With a cable diameter of 10 - 14 mm, with T31 terminals.