Currency EUR
Frequency converters 0.40 kW, 1 AC 200 - 240 V, 50/60 Hz, 2.3 A Rexroth Bosch Group VFC 5610 1AC, R912005384, – T KORP GRUP, OOO | all.biz
Buy Frequency converters 0.40 kW, 1 AC 200 - 240 V, 50/60 Hz, 2.3 A Rexroth Bosch Group VFC 5610 1AC, R912005384,
Frequency converters 0.40 kW, 1 AC 200 - 240 V, 50/60 Hz, 2.3 A Rexroth Bosch Group VFC 5610 1AC, R912005384,
chastotnye_preobrazovateli_040_kw_1_ac_200_240_v
chastotnye_preobrazovateli_040_kw_1_ac_200_240_v

Frequency converters 0.40 kW, 1 AC 200 - 240 V, 50/60 Hz, 2.3 A Rexroth Bosch Group VFC 5610 1AC, R912005384,

In stock
Price:
135 EUR
Payment:
  • Cash,
  • Invoice payment,
  • Visa/Mastercard
  • In detail
Shipping:
Seller
Ukraine, Dnipro
(View map)
+380 
Display phones
Technical characteristics
  • BrandRexroth Bosch Group
  • Country of manufactureGermany
  • Input Voltage200..240В (±10%) V
  • Current Type2,3 A
Description

Frequency converters Rexroth Bosch Group VFC 5610 1AC, R912005384, 0.40 kW, 1 AC 200 - 240 V, 50/60 Hz, 2.3 A

Technical characteristics
  VFC 3610 VFC 5610 EFC 3610 EFC 5610
Entrance 1P 200 VAC Output power 0.4... 2.2 kW
Supply voltage 200. 240B (±10%)
Frequency of network 50/60 Hz of ±5%
3P 400 VAC Output power Severe conditions of operation.: 0.4... 18.5 kW; Normal conditions: 7.5... 22 kW
Supply voltage - 15% 380 IN... 480 IN +10%
Frequency of network 50/60 Hz of ±5%
Exit Output frequency 0... 400 Hz
Law of management V/f V/f, SVC V/f V/f, SVC
Electric motor type Asynchronous engines Asynchronous engines, Synchronous motors
Functions Reloading ability Severe conditions of operation: 150%, 60 with; Normal: 120%, 60 with Severe conditions of operation: 150%, 60 with / 200%, 1s; Normal: 120%, 60 s
Surge protector - EN61800-3 C3
Resolution on frequency Analog 1/1000 from output frequency
Digital 0.01 Hz
Pulse-width Modulation (PWM) 1 kHz... 15 kHz, with an adjustable step of 1 kHz
Range of regulation of speed 1:50 1:200 1:50 1:200
Starting moment 3 Hz for 150% 0.5 Hz for 200% 3 Hz for 150% 0.5 Hz for 200%
1.5 Hz for 100% 1.5 Hz for 100%
Control of the fan Continuous rotation Automatic control on the basis of temperature
Controller PID
Vkh/Vykh of the plug Analog multi - are functional e entrances +10 V +
+5 V +
AI1 0... 10 B/0(4)... 20 ma
AI2 0... 10 B/0(4)... 20 ma
Analog outputs AO1 0... 10 B/0(4)... 20 ma
Digital entrances + 24 V max. 100 ma
DI1... DI5 PNP/NPN of connection
DI5 (pulse entrance) max. 50 kHz
DO1 (Pulse entrance) max. 32 kHz
Exit with an open collector 1
Relay exit 1
Brake module (Chopper) Built-in
The supported options Modbus RTU (standardly), PROFIBUS DP (optionally), CANopen (optionally) Modbus RTU (standardly), PROFIBUS DP (optionally), CANopen (optionally), Multi-Ethernet (optionally)
Conditions okruzh. Wednesdays certificates Ambient temperature - 10 °C to +50 °C (power deceleration in calculation is above 40 °C of 1% for 1 °C) - 10 °C to +55 °C (power deceleration in calculation is above 45 °C of 1% for 1 °C)
Relative humidity  
Max. working frequency  
Degree of protection IP20
Certificates CE CE, UL, cUL, RCM, EAC(Gost R)