- BrandRedington
- Country of manufactureRussia
- Special featureFrost resistant
- Number of componentsTwo component
- KindPolyurethane
Prices are indicated without VAT
REDINGTON SEALANT PU - 2K
2 - component bulk polyurethane sealant.
Product Description:
REDINGTON SEALANT PU - 2K is a 2 - component, self - leveling polyurethane sealant for filling and sealing wide horizontal joints, as well as eliminating dead zones on flat roofs. It is used in the construction and repair of industrial and civil facilities. Compatibility: metal, concrete, brick, wood, PVC, ceramics. For indoor and outdoor use. Color: gray.
Packing: metal buckets with a volume of 12 kg (8kg + 4kg)
Application area:
-
Temperature and shrinkage joints on flat roofs and terraces
-
Elimination of dead zones on flat roofs
-
Wide horizontal movement joints
-
Seams in water tanks and pools
-
Runway seams
Advantages:
-
Versatile and easy to use
-
Does not shrink
-
Elasticity> 500%
-
Frost resistant
-
Repairable
Application steps:
SURFACE PREPARATION:
Seams must be cleaned and dried prior to application. The surface must be free from traces of grease, oil, paraffin, silicone and other substances. If the bottom of the joint is open, a polyethylene foam sealing cord should be used, leaving a fill depth equal to half the joint width.
PADDING:
The primer is selected based on the type and condition of the applied surface. For absorbent surfaces with a residual moisture content of not more than 5% and metal substrates, it is recommended to use REDINGTON WET 5% primer, for surfaces with a residual moisture of 5% - 18% , use REDINGTON WET 18% primer, for PVC - based substrates, use REDINGTON PVC primer, for non - absorbent surfaces such as ceramic tiles and marble use REDINGTON GLASS primer.
APPLICATION:
Stir components A and B with a low - speed mixer (150 - 200 rpm) for 2 - 3 minutes until smooth. Next, fill the seam or stagnant area on the roof with sealant. After applying the sealant, the surface must be smoothed. The ready - made mixture should be used within 20 - 30 minutes at an average temperature of + 20 ° C. The open time can vary depending on the air temperature: decrease with increasing temperature and increase with decreasing temperature.
Main factors:
Index | Meaning | Index | Meaning |
Type of material | 2 - component polyurethane | Operating temperature | from - 40 ° C to + 80 ° C |
Application method | bulk | Mobility resistance of the seam | 25% |
Density | 1.5 g / cm³ (at + 20 ° C) ISO 2811 - 1 | Open time when mixing components "A" and "B" | 20 - 30 minutes |
Hardness | 30 (Shore A), ISO R868 | Accelerated aging test | 1000 hours (ASTM G154) |
Elongation at break | > 500% (ASTM D 412) | Adhesion to concrete | > 1.5 N / mm² |
Dry residue | 100 % | Polymerization time | 5 o'clock |
Dilution | Not recommended | Packaging | 12 kg (8kg + 4kg) |
Application temperature | from + 5 ° C to + 30 ° C | Shelf life | 12 months ( + 5 ° C + 25 ° C) |
Information on all of the company's products can be viewed at https: // ugspecsnab. com /