Technical characteristics
  • Coefficient of performance (COP)91 %
Description

The E-2.5-0.9 boiler - it is high - the economic, vertically water pipe device having a fire chamber and is warmed with products of the fuel burned in it and intended for receiving steam by pressure above atmospheric (0,8 MPas (8kgs/cm2), t = 175 °C) used out of the device.

The copper of "E-2.5-0.9" is calculated for work on gas or fuel oil.

LLC NIP Teplolider suggests to buy the boiler of a series "E" , namely to buy E-2.5-0.9.

E-2.5-0.9 boilers are delivered to the customer by the uniform transportable block in assembled form in a covering with the mounted service equipment. Delivery of a copper with a complete set includes: the gorelochny device, the nutritious pump , the fan , the smoke exhauster , instrumentations , a set of control facilities , shutoff valves , valves and sensors of pressure , a sound siren , the passport of the established form, the maintenance instruction, and also a set of drawings for repair.

The design of the boiler is reliable and safe in operation, the possibility of survey, repair, cleaning, washing and purge of resinous deposits, ashes and slag is provided. E-2.5-0.9 boilers are used for heating needs of inhabited, administrative, educational institutions and other buildings, and also for production needs in the food industry and agriculture.

 

Technical characteristics of steam water pipe coppers

Name of an indicator   E-2,5-0,9 of hypermarket gas      E-2,5-0,9 GMN fuel oil   
Working vapor pressure not an exit, MPa (kgf/cm ²), not less      0,8 (8,0) 0,8 (8,0)
Nominal steam generating capacity, t/h, not less 2.5 2.5
Temperature of saturated steam, s 174,5 174,5
Settlement fuel Gas Liquid, fuel oil
Settlement fuel consumption, not Bol Gas - 210 m3/h Fuel oil - 190 m3/h
Efficiency, % with the economizer 91 91
Efficiency, % without economizer 89 89
Feedwater temperature, s 50 50
The established electric power, KW 12 7.5
Mass of a copper, kg, no more 8100 6400
Dimensions of a copper, m (DKHSHKHV), no more 4,4х3,8х3,6 5,3х2,4х3,2