Features:
* All of the test subjects will done automatically.
* The inner/outer high-volt output value and persistence period can be set separately.
* Test speed is quick, all test subjects will be achieved in 2 seconds.
* The PLC control system comes from Mitsubishi, Made In Japan.
* The relay comes from Schneider, Made In French.
* If the specimen is incompetent, there is a alarm by buzzer and light.
* If the specimen is incompetent, this machine will stop at once and show you which subject is incompetent. Until you push the emergency button it will restart to a new test. And a switch with key can be made to order to replace the high-volt starting button, it is very useful, because when a alarm happen, the operaters can not restart this machine, only after the managers have checked over and restart it by key the machine will work again.
* When test over, the sample will be pushed out automatically, and a "T" or other characters will be marked on it(English characters only).
* 28 plugs can be inserted into the end to perform test, when test over, they will be pushed out together.
NOTICE:
1, Inner high-volt is applied between L, N, E wires, and the outer high-volt is applied between L, N, E wires and jacket.
2, Both 3-wire and 2-wire power plug can be tested by this machine.
Test Objects: Power Plugs
* All of the test subjects will done automatically.
* The inner/outer high-volt output value and persistence period can be set separately.
* Test speed is quick, all test subjects will be achieved in 2 seconds.
* The PLC control system comes from Mitsubishi, Made In Japan.
* The relay comes from Schneider, Made In French.
* If the specimen is incompetent, there is a alarm by buzzer and light.
* If the specimen is incompetent, this machine will stop at once and show you which subject is incompetent. Until you push the emergency button it will restart to a new test. And a switch with key can be made to order to replace the high-volt starting button, it is very useful, because when a alarm happen, the operaters can not restart this machine, only after the managers have checked over and restart it by key the machine will work again.
* When test over, the sample will be pushed out automatically, and a "T" or other characters will be marked on it(English characters only).
* 28 plugs can be inserted into the end to perform test, when test over, they will be pushed out together.
NOTICE:
1, Inner high-volt is applied between L, N, E wires, and the outer high-volt is applied between L, N, E wires and jacket.
2, Both 3-wire and 2-wire power plug can be tested by this machine.
Test Objects: Power Plugs
Items | Explanation | ||
High voltage test | Output voltage | Outside high voltage | (L, N, E and cover) 0-5KV (adjustable) leakage current: 1, 2, 3, 5, 10mA (adjustable) |
Interelectrode high voltage | 0- 5KV (adjustable) | ||
Rated power | 500VA | ||
Profile | 50/60Hz Exchange sine wave |
||
Voltage calibration | within +-5% | ||
Switch | Zero Level Translators | ||
Voltage digital meter | Proportion | 1: 50 | |
Rank | 1.0 CLASS | ||
Fault Judgment | Judgement | The observed value is bigger than the datum value, Shuts off the output voltage and alarm. | |
Enact leakage current value (benchmark value) |
0.5/1/2/3/5/10 mA | ||
Judgement precision | ± 5% | ||
Inspects the no-load output voltage | About 200V 2.5mA stalls, short L, N, and it must alarm. | ||
Dielectric resistance | Output voltage | 500VDC | |
Voltage calibration | ± 5% | ||
benchmark value | 5/100MΩ | ||
Judgment | The measured object insulation resistance value is smaller than the benchmark value, given the failure signal. | ||
Judgment precision | ± 5% | ||
Single polarity andcontinuoustesting | Polarity test | You have to test each wires in sequence. | |
CON test | You don' t have to test each wires in sequence. |
联系卖家