汉语
货币 CNY
Heat pump all in one ( cooling + heating + hot water ) 购买在 佛山
0
购买 Heat pump all in one ( cooling + heating + hot water )
Heat pump all in one ( cooling + heating + hot water )

Heat pump all in one ( cooling + heating + hot water )

有现货
价钱:
3000 CNY
交货:
销售员
中国, 佛山
(地图指示)
+86( 
显示电话
技术特点
  • 牌子Clitech
  • 生产国中国
描述

Technical Parameters:

Word: Heat pump all in one

Model CAM-12XB CAM-16XB CAM-20XB
AC cooling Cooling capacity kW 7.44 9.8 12.4
AC Water flow M³/H 1.28 1.68 2.13
Input power KW 2.58 3.4 4.3
Rated input current A 11.87 16.5 7.6
EER 2.88 2.88 2.88
AC cooling with heat recovery for hot water  Cooling capacity kW 7.8 10 13
AC Water flow M³/H 1.34 1.72 2.24
Heating capacity kW 10.5 14.5 16.5
Hot water output T/H 0.22 0.27 0.35
Input power KW 2.3 3.1 3.7
Rated input current A 10.59 16.2 7.1
EER+COP 7.96 7.88 7.97
AC heating with Hot water  Heating capacity kW 11 14.8 19.00
Hot water output T/H 0.24 0.32 0.41
Input power KW 2.44 3.2 4.07
Rated input current A 11.23 16 7.76
COP 4.51 4.62 4.67
Rated & Max water temp °C 55°C and 60°C
Power source V/PH/HZ 220V/1N/50HZ or 380V/3N/50HZ 380V/3N/50HZ
Noise level dB(A) <50 <54 <55
Unit size W x D x H mm 710*710*810 810*780*1050 810*780*1050
Wood Packing W x D x H mm 810*810*980 910*880*1220 910*880*1220
Net weight Kg 110 165 175
Throttle Type Electronic expansion valve/Thermal expansion valve
Refrigerant Qty kg 3.2 4.8 5.2
Sanyo Compressor Pcs 1 1 1
Protection Built-in protection as overheating protection, sequence protection, undervoltage protection, time-delay start protection etc
Condensor Heat exchanger type Finned tube heat exchanger
Qty pcs 1 1 1
Fan type Axial big twist angle fan
Motor KW 0.2 0.3 0.3
Hot water Heat exchanger type  Efficient tube in tube heat exchanger with Max working pressure 1000 kPa
Qty pcs 1 1 1
Water flow M³/H 1.89 2.45 3.27
Pressure Loss KPa 27 30 32
Pipe size mm 20 25 25
Air Conditioner Heat exchanger type Efficient tube in tube heat exchanger
Quantity 1 1 1
water flow M³/H 1.34 1.68 2.24
Pressure Loss Kpa 12 13 13
Pipe size mm 20 25 25
Water side max working temp kPa 1000 1000 1000
1.Rated cooling working condition: Air source side inlet water temp is 35°C, AC side inlet water temp  is 12°C, outlet water temp  is 7°C
2.Rated heating&hot water condition: Air source side DB/WB is 20°C/15°C,initial hot water temp 15°C, ending hot water temp 55°C;AC side inlet water temp 40°C,outlet water temp 45°C.
3.Rated cooling&hot water working condition: initial hot water temp 15°C,ending hot water temp 55°C;AC side inlet water temp 12°C,outlet water temp 7°C.

 

This CAM series Air to water heat pump Heating Cooling and Hot water unit can connect to indoor fan coil unit for house cooling in summer and house heating in winter;  sanitary hot water produced all year around. 