Technical characteristics
  • Country of manufactureChina
  • Type of hydraulic machineGerotor
Description

1. MODEL orderingIVS - HPU - A - S4005 – S

1 2 3  4 5

Tabe - 1: ManufactureIVS

Tabe - 2: Product: HPU - Hydraulic Power Unit

Tabe - 3: Operation code M - manual / A - auto

Tabe - 4: Model Data S - single acting; D - double acting;

S/D4 * * * - series, S/D5 * * * - series, S/D7 * * * - series See Chart - 1

Tabe - 5: S/P/C

S: Static pressure or burst

1. Static pressure: Conduct static pressure holding testing and record the leak volume (pressure differential)

2. Burst function: Conduct burst testing within the max. Output pressure and record the peak pressure

3. Or combine the static pressure testing and burst testing

P: Pulse, and it is only for the single acting pumps, frequency 0.5HZ, and the pulses deformation will be less than the pump volume when the pulse pressure within the static pressure

C: Auto calibration for pressure gauges.

Chart - 1

4 * * * series

 Pump Ratio

Volume

Static pressure Kgf/cm2

Single acting

Double acting

Min.

Max.

S - Volume
per Stroke
/ml

Max. Volume ml/min

D - Volume
per Stroke
/ml

Max. Volume ml/min

005

42

4200

84

8400

2.5

35

010

22

2200

44

4400

5

70

020

12

1200

24

2400

10

140

030

7.5

750

15

1500

15

210

040

6

600

12

1200

20

280

060

4

400

8

800

30

420

110

2

200

4

400

55

770

155

1.5

150

3

300

77.5

1085

240

1

100

2

200

120

1680

300

0.8

80

1.6

160

150

2100

5 * * * series

Pump Ratio

Volume

Static pressure Kgf/ cm2

Pump Ratio

Single acting

Double acting

Min.

Max.

Volume
per Stroke
/ml

Max. Volume  ml/min

Volume
per Stroke
/ml

Max. Volume  ml/min

005

90

9000

180

18000

2.5

35

010

42

4200

84

8400

5

70

012

36

3600

72

7200

6

84

020

22.5

2250

45

4500

10

140

025

16

1600

32

3200

12.5

175

030

14

1400

28

2800

15

210

035

12

1200

24

2400

17.5

245

055

7.5

750

15

1500

27.5

385

070

6

600

12

1200

35

490

085

5

500

10

1000

42.5

595

105

4

400

8

800

52.5

735

140

3

300

6

600

70

980

195

2

200

4

400

97.5

1365

280

1.5

150

3

300

140

1960

440

1

100

2

200

220

3080

555

0.75

75

1.5

150

277.5

3885

7 * * * series

Pump Ratio

Volume

Static pressure Kgf/ cm2

Single acting

Double acting

Min.

Max.

Volume
per Stroke
/ml

Max. Volume ml/min

Volume
per Stroke
/ml

Max. Volume ml/min

005

290

29000

580

58000

2.5

35

010

146

14600

292

29200

5

70

020

66

6600

132

13200

10

140

025

55

5500

110

11000

12.5

175

035

40.5

4050

81

8100

17.5

245

055

24.5

2450

49

4900

27.5

385

095

15

1500

30

3000

47.5

665

145

10

1000

20

2000

72.5

1015

180

8

800

16

1600

90

1260

240

6

600

12

1200

120

1680

330

4

400

8

800

165

2310

460

3

300

6

600

230

3220

740

2

200

4

400

370

5180

NOTES1. S - Single acting; D - Double acting

 2. The output pressure and flow rate act as reference for order and their real valve will vary according to pressure and driven air

                   

Chart - 1

2. User facility on site

1. Air supply 7 - 10bar

2. Power supply for auto type 220V 50HZ 500W

3. Fit indoor safe area;

4. Please consult for I. P protection and hazard area

3. Features

1. Pressure control:≤1% F. S

2. Leak rate:≤1% of set point

3. Sampling frequency0~1000 Hz

4. Stable Pressure:≤1% F. S

5. Inlet Medium inlet 1/2”NPTF; Air inlet,1/2”NPTF

6. Outlet 100MPa, HF6

7. Relief port3/8”NPTF

4. Material

1. Liquid contact: tube and fitting - SS;

2. Pump material can be optional in copper alloy and SS

3. Cabinet: Carbon steel/SS

5. Schematic

6. Reference Profile

Size: L600mm * W500mm * H450mm

WeightVarys from models

Contact the seller
Electric hydraulic power unit
Electric hydraulic power unit
We recommend to see
Shipping method
Compare0
ClearSelected items: 0