Casing explosion-proof for the GuardLiner Ex100 control uni
Products from producer
In stock
Reconfirm the price with seller
- Customer pickup,
- Courier
- In detail
Description
Model | GuardLiner Ex100 |
Certified parameters | |
Production standard | GOST P MEK 60079-0-2011 and 60079-1-2008 |
Design type | Explosion-proof case |
Explosion protection class | 1 Exd IIB T6 Gb |
Ensuring explosion proofness. | Explosion proofness of a casing of a chamber according to requirements of GOST P MEK 60079-1-2008 is provided with the conclusion of electric parts in a blast-tight cover which maintains explosion pressure in it, and excludes transfer of explosion to environment.
At production the cover of a casing of a chamber is tested pressure up to 1,5 MPas for providing its vzryvoustoychivost. |
Tightness class | IP66 |
Operating conditions of environment | The gas group is lower than IIC (hydrogen, acetylene, ethylene, gas from the coke furnace, methyl vapors, etc.) and flammable dust |
Working temperature | - 60 ° C ~ +60osprimechaniye 1 |
Relative humidity of air | ≤ 95% (at +25os) |
Inputs of a cable | 6XG1/2" explosion-proof input of a cable, diameter of an internal opening of Ø 14 |
Mekhanicheskiyeparametra | |
Material | Carbonaceous steel / Stainless steel (brands 304/316/316L) |
Sizes (DKHSHKHV) | 230 x 300 x 184 mm |
Internal sizes | 255 x 225 x 120 mm |
Weight | 21 kg |
Built-in controller | |
Operating mode | The main |
Control interface | Half-duplex RS-485 |
Protocol of management | PELCO-D (other protocols are established at the request of the customer) |
Speed of management in bauds | 1200, 4800, 9600 |
Power supply parameters | |
Tension | 24 V post.tok / 220 V alternating current |
Current | 2 AND / 0,5 AND |
Other parameters | |
Existence of the decoder | On demand |
Existence of a heating system | On demand |
Contact the seller
Casing explosion-proof for the GuardLiner Ex100 control uni