Currency EUR
Cable universal for data transmission KUPDNG (A) VEK on THAT BY 500017371.077-2015 – Shchuchinskij zavod Avtoprovod, OAO | all.biz
Buy Cable universal for data transmission KUPDNG (A) VEK on THAT BY 500017371.077-2015
Cable universal for data transmission KUPDNG (A) VEK on THAT BY 500017371.077-2015

Cable universal for data transmission KUPDNG (A) VEK on THAT BY 500017371.077-2015

Products from producer
In stock
Reconfirm the price with seller
Payment:
Shipping:
Seller
Belarus, Schuchin
(View map)
+375 
Display phones
Technical characteristics
  • BrandЩучинский завод Автопровод, ОАО
  • Country of manufactureBelarus
  • Lengthв ассортименте "
  • Wattageв ассортименте W
  • Conductor materialCopper
  • Type of power cable connectionStripped
  • Minimum bend radiusв ассортименте "
Description
APPOINTMENT:

Cables are intended for signaling to the control equipment, are used for remote control of executive mechanisms of management, for interinstrument connection at a voltage up to 600 V of alternating current with a frequency up to 400 Hz or to 1000 V of a direct current.

Cables are made brands:

- KUPD V - a cable with flexible copper tinned veins or couples, with isolation from plastic compound PVC, with the water blocking tape, in a protective hose from plastic compound PVC;

- KUPD EV - a cable with the flexible copper tinned veins twisted in pairs in the individual screen, with isolation from plastic compound PVC, with the water blocking tape, in a protective hose from plastic compound PVC;

- KUPD VE - a cable with flexible copper tinned veins or couples, with isolation from plastic compound PVC, in the general screen, with the water blocking tape, in a protective hose from plastic compound PVC;

- KUPD EVE - a cable with the flexible copper tinned veins twisted in pairs in the individual screen, with isolation from plastic compound PVC, in the general screen, with the water blocking tape, in a protective hose from plastic compound PVC;

- KUPD VK - a cable with flexible copper tinned veins or couples, with isolation from plastic compound PVC, with the water blocking tape, in wire armor, in a protective hose from plastic compound PVC;

- KUPD EVK - a cable with the flexible copper tinned veins twisted in pairs in the individual screen, with isolation from plastic compound PVC, with the water blocking tape, in wire armor, in a protective hose from plastic compound PVC;

- KUPD VEK - a cable with flexible copper tinned veins or couples, with isolation from plastic compound PVC, in the general screen, with the water blocking tape, in wire armor, in a protective hose from plastic compound PVC;

- KUPD EVEK - a cable with the flexible copper tinned veins twisted in pairs in the individual screen, with isolation from plastic compound PVC, in the general screen, with the water blocking tape, in wire armor, in a protective hose from plastic compound PVC;

- KUPDNG (A) B - a cable with flexible copper tinned veins or couples, with isolation from plastic compound PVC, with the water blocking tape, in a protective hose from PVC of plastic compound of the lowered combustibility;

- KUPDNG (A) EV - a cable with the flexible copper tinned veins twisted in pairs in the individual screen, with isolation from plastic compound PVC, with the water blocking tape, in a protective hose from PVC of plastic compound of the lowered combustibility;

- KUPDNG (A) VE - a cable with flexible copper tinned veins or couples, with isolation from plastic compound PVC, in the general screen, with the water blocking tape, in a protective hose from PVC of plastic compound of the lowered combustibility;

- KUPDNG (A) EVE - a cable with the flexible copper tinned veins twisted in pairs in the individual screen, with isolation from plastic compound PVC, in the general screen, with the water blocking tape, in a protective hose from PVC of plastic compound of the lowered combustibility;

- KUPDNG (A) BK - a cable with flexible copper tinned veins or couples, with isolation from plastic compound PVC, with the water blocking tape, in wire armor, in a protective hose from PVC of plastic compound of the lowered combustibility;

- KUPDNG (A) EVK - a cable with the flexible copper tinned veins twisted in pairs in the individual screen, with isolation from plastic compound PVC, with the water blocking tape, in wire armor, in a protective hose from PVC of plastic compound of the lowered combustibility;

- KUPDNG (A) VEK - a cable with flexible copper tinned veins or couples, with isolation from plastic compound PVC, in the general screen, with the water blocking tape, in wire armor, in a protective hose from PVC of plastic compound of the lowered combustibility;

- KUPDNG (A) EVEK - a cable with the flexible copper tinned veins twisted in pairs in the individual screen, with isolation from plastic compound PVC, in the general screen, with the water blocking tape, in wire armor, in a protective hose from PVC of plastic compound of the lowered combustibility;

- KUPDNG (A)-LS B - a cable with flexible copper tinned veins or couples, with isolation from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission, with the water blocking tape, in a protective hose from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission;

- KUPDNG (A)-LS EV - a cable with the flexible copper tinned veins twisted in pairs in the individual screen, with isolation from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission, with the water blocking tape, in a protective hose from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission;

- KUPDNG (A)-LS VE - a cable with flexible copper tinned veins or couples, with isolation from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission, in the general screen, with the water blocking tape, in a protective hose from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission;

- KUPDNG (A)-LS EVE - a cable with the flexible copper tinned veins twisted in pairs in the individual screen, with isolation from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission, in the general screen, with the water blocking tape, in a protective hose from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission;

- KUPDNG (A)-LS BK - a cable with flexible copper tinned veins or couples, with isolation from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission, with the water blocking tape, in wire armor, in a protective hose from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission;

- KUPDNG (A)-LS EVK - a cable with the flexible copper tinned veins twisted in pairs in the individual screen, with isolation from PVC of plastic compound of the lowered fire danger with low gas and smoke emission, with the water blocking tape, in wire armor, in a protective hose from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission;

- KUPDNG (A)-LS VEK - a cable with flexible copper tinned veins or couples, with isolation from PVC of plastic compound of the lowered fire danger with low gas and smoke emission, in the general screen, with the water blocking tape, in wire armor, in a protective hose from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission;

- KUPDNG (A)-LS EVEK - a cable with the flexible copper tinned veins twisted in pairs in the individual screen, with isolation from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission, in the general screen, with the water blocking tape, in wire armor, in a protective hose from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission;

- KUPDNG (A)-FRLS B - a cable fire-resistant with the flexible copper tinned veins twisted in pairs with isolation from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission, with the water blocking tape, in a protective hose from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission;

- KUPDNG (A)-FRLS EV - a cable fire-resistant with the flexible copper tinned veins twisted in pairs in the individual screen, with isolation from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission, with the water blocking tape, in a protective hose from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission;

- KUPDNG (A)-FRLS VE - a cable fire-resistant with the flexible copper tinned veins twisted in pairs with isolation from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission, in the general screen, with the water blocking tape, in a protective hose from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission;

- KUPDNG (A)-FRLS EVE - a cable fire-resistant with the flexible copper tinned veins twisted in pairs in the individual screen, with isolation from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission, in the general screen, with the water blocking tape, in a protective hose from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission;

- KUPDNG (A)-FRLS BK - a cable fire-resistant with the flexible copper tinned veins twisted in pairs with isolation from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission, with the water blocking tape, in wire armor, in a protective hose from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission;

- KUPDNG (A)-FRLS EVK - a cable fire-resistant with the flexible copper tinned veins twisted in pairs in the individual screen, with isolation from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission, with the water blocking tape, in wire armor, in a protective hose from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission;

- KUPDNG (A)-FRLS VEK - a cable fire-resistant with the flexible copper tinned veins twisted in pairs with isolation from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission, in the general screen, with the water blocking tape, in wire armor, in a protective hose from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission;

- KUPDNG (A)-FRLS EVEK - a cable fire-resistant with the flexible copper tinned veins twisted in pairs in the individual screen, with isolation from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission, in the general screen, with the water blocking tape, in wire armor, in a protective hose from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission.

Appendix: The screen executed from an alyumofleks is designated "E", the screen from copper a provolok is designated by "Em", the screen from copper tinned a provolok is designated "Al".

Design

Conducting vein: copper tinned wire. Correspond to a class 4 in accordance with GOST 22483.

Number of veins: 2,3,4,5,6,7,8,10,12,14,16,19

Number of couples: 1,2,3,4,5,6,7,8,10,12,14,16,19

Sections there lived the mm2: 0,5; 0,75; 1,0; 1,5; 2,5

Winding: for cables with an index ng (A)-FRLS over each conducting vein is imposed a winding with overlapping not less than 30% of a slyudosoderzhashchy tape with a nominal thickness of 0,14 mm.

Isolation of a vein: PVC by plastic compound, conducting veins of cables of execution ng (A)-LS and conducting veins with a winding from a slyudosoderzhashchy tape of cables of execution ng (A)-FRLS-PVH plastic compound of the lowered fire danger with a low gazo-and smoke emission are isolated. For cables of a climatic modification of HL1 of PVC plastic compound has to be frost-resistant.

Twist: the isolated conducting veins of cables to pair twist are twisted among themselves in couples with a step no more than 80 mm. In each couple the isolated veins differ from each other in color of isolation. It is allowed to execute color of isolation of veins in the form of one color strip. The isolated veins, screened couples of cables with the individual screen or unscreened couples have to be twisted in the core by povivny or puchkovy twist. In each poviv of the core there have to be two calculating veins or pairs of veins differing in the color from each other and from other veins or couples of poviv. Calculating veins or couples have to settle down nearby. Parallel laying of couples is allowed.

Tape: over the twisted veins, unscreened or screened couples, the water blocking tape is imposed with overlapping. It is allowed over the twisted core or over imposing of the fastening winding which is water blocking tapes from a polyamide or polietilentereftalatny film.

Screen: the screen has to be imposed on the twisted couples of cables with the individual or combined screen before twist in the core. The screen can be executed in the form of the shielding braid from a copper or copper tinned wire with a diameter no more than 0,20 mm for cables with a section up to 0,75 mm ² inclusive and no more than 0,26 mm for cables by section above 0,75mm ² and with a density not less than 65%, or in the form of a winding from an alyumofleks and a contact wire from a copper tinned wire with a diameter not less than 0,4 mm. It is allowed under the screen on the twisted couples to impose a polietilentereftalatny film. Designation of a type of the screen is specified in wire brand (E - alyumofleks, Em - a braid from a copper wire, Al - a braid from a copper tinned wire).

Isolation: over the water blocking tape (for cables without the general screen), over the general screen (for cables with the general screen) cables with wire armor zone isolation from plastic compound PVC, for execution cables ng (And) - LS and ng (A)-FRLS - from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission is imposed. For a cable of a climatic modification of HL1 of PVC plastic compound has to be frost-resistant.

Armor: over zone isolation of armor cables the armor from steel zinced a provolok with a nominal diameter of 0,3 mm is imposed. Density of imposing of wire armor not less than 60%.

Protective hose: over the water blocking tape (for cables without the general screen) or over the general screen (for cables with the general screen) unarmoured cables and over wire armor of armor cables the protective hose from plastic compound PVC, for cables of a climatic modification of HL1 - from frost-resistant PVC of plastic compound, for execution cables ng (And) - from PVC of plastic compound of the lowered combustibility, for execution cables ng (A)-LS and ng (And) - FRLS - from PVC of plastic compound of the lowered fire danger with a low gazo-and smoke emission is imposed. For a cable of a climatic modification of HL1 of PVC plastic compound has to be frost-resistant. Color of a protective hose makes a reservation at the order. In the absence of the instruction color of a protective hose of fire-resistant cables red or orange, color of a protective hose of other cables - black.

Technical characteristics

The electric resistance of isolation of cables counted for 1 km of length and temperature of 20 °C has to be not less than 10 megohms, at a temperature of 70 °C - not less than 0,1 megohms.

The working capacity of couples counted for 1 km of length has to be no more:

- for the section of 0,5 mm ² - 120 nf;

- for the section of 0,75 mm ² - 130 nf;

- for the section of 1,0 mm ² - 150 nf;

- for the section of 1,5 mm ² - 160 nf;

- for the section of 2,5 mm ² - 165 nf.

The wave resistance of couples counted for 1 km of length has to be:

- for the section of 0,5 mm ² - 75 Ohms;

- for the section of 0,75 mm ² - 70 Ohms;

- for the section of 1,0 mm ² - 65 Ohms;

- for the section of 1,5 mm ² - 60 Ohms;

- for the section of 2,5 mm ² - 55 Ohms.

Cables have to be resistant to a bend.

The protective hose of cables has to be tight.

Cables are steady against influence of the increased ambient temperature plus 70 °C.

Cables are steady against influence of the lowered ambient temperature: executions of UHL1-minus 50 °C, executions of HL1-minus 60 °C in the conditions of the fixed installation and minus 15 °C in the conditions of assembly bends.

Cables are steady against change of ambient temperature: from minus 40 °C to plus 70 °C for execution of UHL1 and from minus 60 °C to plus 70 °C for execution of HL1.

Cables have to be resistant to long influence of relative humidity of air: to 93% at ambient temperature to plus 35 °C.

Cables have to be steady against longitudinal distribution of water.

Average service life of cables has to make not less than 15 years.

The average service life established by these specifications is provided on condition of observance of rules of storage, transportation, installation and operation.

Cables have to be reeled up on drums or in bays.

Cables should not extend burning at single laying.

Execution cables ng (And), ng (A)-LS, ng (A)-FRLS should not extend burning when laying in bunches.

Requirements for smoking

Smoking during the burning and decay of cables of execution ng (A)-LS, ng should not lead (A)-FRLS to decrease in a light stream in a test chamber more than for 50%.

Requirements of fire resistance

Fire resistance of cables fire-resistant executions ng (A)-FRLS has to be not less than 30 min.

Cables are intended for operation at ambient temperature from minus 60 °C to plus 70 °C in the conditions of the fixed installation and from minus 15 °C to plus 70 °C in the conditions of assembly bends.

Fire-resistant cables are intended for cable lines of food and management of the equipment functioning at the fire.

Cables can be operated at relative humidity of air to 93% at a temperature of 35 °C.

The minimum radius of a bend at installation and operation has to be not less than twenty maximum diameters of a cable.

The maximum temperature of a conducting vein at operation should not exceed 70 °C.

Admissible temperature of veins in overload conditions no more than 90 °C. Period of operation in overload conditions no more than 8 h a day and no more than 1000 h for service life.

Extreme temperature of conducting veins of fire-resistant cables under the terms of not ignition at short circuit 400 ºС. Time of short circuit no more than 5 sec.

Shelf life of cables on condition of observance of storage conditions of 5 years.
Comments about the company  Shchuchinskij zavod Avtoprovod, OAO
100%
of positive feedback from the 2
50% of responses during the day
50% of transactions executed in time
100% of actual goods description
This means that 100% of buyers found cooperation with this company successful and recommend this seller
all (2) positive (2) negative (0)
Good
Anonymous
02.05.2018
Allbizconfirms appeals
Allbiz confirms a receiver's contacting via resource
Prompt response: Within one hour
Was the order is executed in time: Yes
Corresponding of goods/services description: Yes
Good
Anonymous
27.11.2017
Allbizconfirms appeals
Allbiz confirms a receiver's contacting via resource
Цена нас устроила. Но если учитывать транспортные расходы, то мы взяли из Минска попутным транспортом и нам оказалось это более выгодно
Prompt response: A few days later
Was the order is executed in time: I can not appreciate
Corresponding of goods/services description: Yes
Contact the seller
Cable universal for data transmission KUPDNG (A) VEK on THAT BY 500017371.077-2015
Cable universal for data transmission KUPDNG (A) VEK on THAT BY 500017371.077-2015
Shipping method
Payment method
Compare0
ClearSelected items: 0