Currency EUR
Cable of control and management KPBPNG (A)-HF on TU 16.K71-304-2001 – Shchuchinskij zavod Avtoprovod, OAO | all.biz
Buy Cable of control and management KPBPNG (A)-HF on TU 16.K71-304-2001
Cable of control and management KPBPNG (A)-HF on TU 16.K71-304-2001

Cable of control and management KPBPNG (A)-HF on TU 16.K71-304-2001

Products from producer
In stock
Reconfirm the price with seller
Payment:
Shipping:
Seller
Belarus, Schuchin
(View map)
+375 
Display phones
Technical characteristics
  • BrandЩучинский завод Автопровод, ОАО
  • Country of manufactureBelarus
  • Minimum bend radiusв ассортименте "
  • Outside diameterв ассортименте "
  • Conductor materialCopper
Description
Appointment:

Cables are intended for transfer and distribution of the electric power in stationary installations at a rated alternating voltage of 0,66 and 1 KV with a frequency up to 100 Hz, including for operation on the nuclear power plants (NPP) out of a germozona.

Cables are made brands:

Cable brand Name of a cable Primary scope
KPPGNG (And) - HF Cable control with copper veins, with isolation and a cover from the polymeric compositions which are not containing halogens The same
KPPGENG (And) - HF The same, in the general screen The same
KPBPNG (And) - HF Cable control with copper veins, with isolation and a protective hose from the polymeric compositions which are not containing halogens, armor The same, with danger of mechanical damages at operation

* HF-in designation of brands means, not containing halogens (Halogen-Free)

Design

Conducting vein: copper wire

Nominal section and number of veins of control cables have to correspond:

Nominal section of a vein, mm2 Number of veins in a cable
1,0; 1,5; 2,5; 4; 5; 7; 10; 14; 19; 27; 37; 52
4; 6 4; 7; 10

Multicore cables have all veins of equal section. Four-vein cables with veins with a nominal section of 25 mm2 and more can have one vein of smaller section (zero or grounding). The conducting vein of smaller section can be round or sector, single-wire or there is a lot of wire condensed depending on a class of the main veins in a cable.

Name of a vein Nominal section of a vein, mm2
The main 25 35 50 70 95 120 150 185 240 300 400
Zero or grounding 16 16 25 35 50 70 70 95 120 150 185

Isolation: conducting veins of cables have to be isolated by the polymeric composition which is not containing halogens.

Twist: the isolated veins of multicore cables have to be twisted in the core.

For giving to the power cable of almost round form, internal and external intervals between the isolated veins have to be filled. The internal interval has to be filled kordely, vypressovanny of the polymeric composition which is not containing halogens. The isolated veins with a nominal section up to 16 mm inclusive can be twisted without filling of internal filling between them.

Cover: On the twisted isolated veins of multicore cables of all brands and over isolation of single-conductor cables, the internal extruded cover from the polymeric composition which is not containing halogens which has to fill intervals between the twisted veins has to be imposed.

Screen: over an internal cover of a cable of brand KPPGENG (A)-HF imposed the screen in the form of a winding with overlapping from a copper foil / a copper tape or an aluminum foil / folgirovannogo a composite flexible alyumofleks with an aluminum layer.

Along the screen from aluminum foil or an alyumofleks it is longitudinal the contact copper tinned wire is laid.

Armor: over an internal cover of a cable of brand KPBPNG (And) - HF is imposed armor from two steel galvanized tapes.

Cover: over an internal cover of a cable of brand KPPGNG (And) - the external cover from the polymeric composition which is not containing halogens is imposed.

Protective hose: over armor of a cable of brand KPBPNG (A)-HF imposed the protective hose from polymeric composition which is not containing halogens.

Technical characteristics

Cables control make 0,66 kV on a rated alternating voltage.

The electric resistance of isolation of cables counted for temperature of 200 C and 1 km of length for isolation from the sewed polyethylene has to be not less than 150 Megohms, and for isolation from the polymeric compositions which are not containing halogens there has to be a following:

Nominal section of a vein, mm2 Electric resistance of isolation, Megohm, not less
1 and 1,5 12,3
2,5 12,0
4 10,1
6 8,7
10 7,1
16 5,8
25 5,6
35 4,9
50 4,8
70,95 4,1
120,150,185 3,7
240 3,6
300 3,5
400 3,3
500 3,2
625,630 2,9
800 2,6
1000 2,5

Cables have to be steady against a navivaniye.

Cables are intended for operation at ambient temperature from minus 50 °C to plus 50 °C.

Cables can be operated at relative humidity of air to 98% at a temperature up to 35 °C.

Requirements for indicators of fire safety

Cables should not extend burning at group laying on category A.

Execution cables ng (And), ng (A)-LS, ng (A)-FRLS should not extend burning when laying in bunches.

Requirements for smoking

Smoking during the burning and decay of cables should not lead to decrease in transparency in a test chamber more than for 40%.

Service life of cables not less than 30 years.

Comments about the company  Shchuchinskij zavod Avtoprovod, OAO
100%
of positive feedback from the 2
50% of responses during the day
50% of transactions executed in time
100% of actual goods description
This means that 100% of buyers found cooperation with this company successful and recommend this seller
all (2) positive (2) negative (0)
Good
Anonymous
02.05.2018
Allbizconfirms appeals
Allbiz confirms a receiver's contacting via resource
Prompt response: Within one hour
Was the order is executed in time: Yes
Corresponding of goods/services description: Yes
Good
Anonymous
27.11.2017
Allbizconfirms appeals
Allbiz confirms a receiver's contacting via resource
Цена нас устроила. Но если учитывать транспортные расходы, то мы взяли из Минска попутным транспортом и нам оказалось это более выгодно
Prompt response: A few days later
Was the order is executed in time: I can not appreciate
Corresponding of goods/services description: Yes
Contact the seller
Cable of control and management KPBPNG (A)-HF on TU 16.K71-304-2001
Cable of control and management KPBPNG (A)-HF on TU 16.K71-304-2001
Shipping method
Payment method
Compare0
ClearSelected items: 0