- Country of manufactureRussia
- Designation of boilerTwo-circuit (heating+dhw)
- Fuel loading methodManual
- Method for removal of waste gasesChimney
- Combustion chamber designClosed
- ColorBlue
- Heat-carrierWater
- Installation methodFloor standing
- Coefficient of performance (COP)96 %
- Thermal Power13 kW
- Heat exchanger materialSteel
We produce solid fuel boilers Pyrolysis RABIKA.
In stock. Send in any region.
Fuel for boiler - not chopped firewood, wood pellets, coal, combustible solid waste.
It is possible to install the gas bitter and apply natural gas.
Boiler advantages RABIKA13
- Really economical, consumes little firewood, fuel is necessary to lay only 2 times a day;
- Very reliable (thick steel, special design, a flat heat exchanger, technological hatches for easy cleaning of the furnace walls, the heat exchanger and the burner);
- The boiler heats the water quickly and keeps it hot for a long time. It works as a heat accumulator (due to the increased heat exchanger inside the boiler);
- Increased insulation exterior walls (combined insulation thermal insulation applied mastic + basalt insulation);
- The boiler is not subject to technical supervision, does not require approval of the company supplier of natural gas, there are no claims of environmental services;
- Safe to use. No hot surfaces.
- Fully compliant with fire protection requirements.
SPECIFICATIONS
Output in kW | thirteen |
Output in kW | 5 - 13 |
The area of heated space in m² (ceiling height 3m) | 150 |
The volume of heated space, m³ | 450 |
The optimum operating temperature of the coolant, ° C | 65 - 95 |
Allowable operating pressure, bar | 2, 5 |
Length mm | 550 |
Width | 500 |
Height mm | 1750 |
The total weight of the boiler, kg | 195 |
The volume of the combustion chamber, m³ | 0.12 |
The area of heat removal in the heat exchanger of the boiler, m² | 2.78 |
Maximum loading wood with a humidity of 30% , kg | fifteen |
The amount of water in the heat exchanger, l | 110 |
Wood consumption per day at the rated output, kg | 45 |
Wood consumption per day at rated power m³ | 0, 1 |
Combustion Duration Cycle |
from 5 to 8 hours |
efficiency | Gasification mode above 80% with water gasification gas regime above 90% |
Diameter flow and return DN. mm | 32 |
The diameter of the pipe to drain the coolant control. mm | 20 |
The diameter of the pipe connection of the valve, mm | fifteen |
Chimney diameter d, mm | 159 |
Send us a request. We respond promptly.
Boilers are available in their original packaging. We send the customer within a few days.
The products are certified and regularly gives warmth to our customers for many years.
For commercial organizations offer cooperation dealer conditions.